When it comes to metal salt spray testing, these key issues must be clearly understood!


Salt is one of the most ubiquitous compounds in the world. It can be found in oceans, the atmosphere, on land surfaces, as well as in lakes and rivers. Consequently, it’s virtually impossible to prevent items from being exposed to salt spray. The effects of salt-spray environments on electrical and electronic equipment rank second only to those caused by temperature, vibration, damp heat, and sand/dust conditions. Therefore, as Environmental Simulation Testing One of them, the salt spray test, is an important accelerated test used to evaluate the anti-corrosion performance of protective coating systems.

1. Why Conduct Salt Spray Testing

Metal corrosion is a spontaneous oxidation process. In salt-spray environments, the presence of salt-spray liquid as an electrolyte significantly increases the likelihood of microcells forming within the metal, accelerating the electrochemical corrosion process. This leads to rusting and blistering of both the metal itself and its protective coatings, ultimately causing structural and fastener failures. Additionally, corrosion can clog or bond moving parts in mechanical components and assemblies, resulting in jamming or malfunction of moving elements. In more subtle cases, it may even cause open circuits or short circuits in fine wires and printed circuit boards, as well as component lead fractures. Meanwhile, the high conductivity of the salt solution dramatically reduces the surface and volume resistances of insulators. Moreover, the resistance between the salt-spray corrosion products and the dried crystalline residues (salt particles) tends to be higher than that of the original metal, further increasing local resistance and voltage drops. This, in turn, can interfere with electrical operations and severely compromise the overall electrical performance of the product.

Environmental Simulation There are three types of salt spray tests: the Neutral Salt Spray Test (NSS), the Acetic Acid Salt Spray Test (AASS), and the Copper-Accelerated Acetic Acid Salt Spray Test (CASS, also known as Copper Chloride Acetic Acid Salt Spray Test). Among these, the Neutral Salt Spray Test is the most widely used. This test is primarily employed to evaluate both metal materials and metallic or non-metallic inorganic coatings applied to metals, as well as to assess coating systems. In contrast, the Acetic Acid Salt Spray Test and the Copper-Accelerated Acetic Acid Salt Spray Test are typically reserved for examining metallic coatings only—and are not suitable for testing organic coatings.

Environmental Simulation The purpose of a salt spray test is to evaluate the salt spray corrosion resistance quality of products or metallic materials, and the interpretation of its results serves as a key factor in assessing product quality. Determining whether these results are accurate and reasonable is crucial for properly measuring the salt spray corrosion resistance performance of both the product and its coating. Test outcomes typically include phenomena such as blistering, rusting, reduced adhesion, and the spread of corrosion from scratch marks. Since Environmental Simulation The relevant standards for evaluating salt spray test results are not widely adopted, and the methods for determining these results are still under discussion.

5d78fbfdcc429f032d8d385a15db31c

Although Environmental Simulation The salt spray test is an effective testing method. However, since numerous factors influence corrosion, a material’s resistance to salt spray alone cannot reliably predict its performance against other corrosive environments. Therefore, the results of a salt spray test should not be used as a direct guide for assessing a material’s overall corrosion resistance in all conditions. Similarly, a material’s behavior during the test does not necessarily reflect its actual corrosion resistance when put into practical use.

Nevertheless, the environmental simulation salt spray test method can still be used as a way to evaluate the materials being tested.

2. Which products require salt spray testing?

Environmental simulation salt spray testing is an important method for evaluating the corrosion resistance of electrical and electronic products, as well as metal materials. The products typically requiring this environmental simulation test include the following:

(1) Steel surfaces plated with copper + nickel + chromium, or nickel + chromium;

(2) Nickel + chromium plating on copper or copper alloy surfaces;

(3) 300 series or 400 series stainless steel with nickel + chromium plating on the surface;

(4) Copper + nickel + chromium plating on aluminum or aluminum alloy surfaces;

(5) Zinc alloy surface plated with copper + nickel + chrome;

(6) Plastic electroplated parts.

3. Salt Spray Testing and Its Real-World Relevance

Environmental Simulation The salt spray test is an environmental test that primarily uses salt spray testing equipment to simulate salt-spray conditions, thereby evaluating the corrosion resistance of products or metallic materials.

It is divided into two main categories: one is the natural environmental exposure test, and the other is the artificial accelerated salt spray simulation test. The artificial salt spray simulation test uses a testing device with a specific volume—known as a salt spray chamber—to create a controlled salt spray environment within its chamber, thereby evaluating the product's salt spray corrosion resistance performance and quality.

Compared to natural environments, the chloride salt concentration in its salt spray environment can be several or even dozens of times higher than that found in typical natural conditions, significantly accelerating the corrosion rate. As a result, conducting salt spray tests on products yields results much more quickly. For instance, while a product sample exposed naturally might take up to a year to show noticeable corrosion, testing under artificially simulated salt spray conditions—specifically, just 24 hours—is often sufficient to produce comparable outcomes.

4. Three Salt Spray Tests for Environmental Simulation Experiments

Environmental Simulation Test – Neutral Salt Spray Test (NSS Test) It is one of the earliest and currently the most widely used accelerated corrosion testing methods. This method employs a 5% sodium chloride saltwater solution, with the pH adjusted to a neutral range (6–7), as the spray solution. The test temperature is consistently maintained at 35°C, and the salt spray deposition rate must fall between 1 and 2 ml/80 cm²·h.

Environmental Simulation Test – Acetate Salt Spray Test (ASS Test) It was developed based on the neutral salt spray test. In this method, a small amount of glacial acetic acid is added to a 5% sodium chloride solution, reducing the pH value to around 3 and making the solution acidic. As a result, the resulting salt spray also shifts from neutral to acidic. Notably, this accelerated corrosion test exhibits a corrosion rate approximately three times faster than the standard NSS test.

Environmental Simulation Test – Copper Salt Accelerated Acetate Salt Spray Test (CASS Test) It’s a rapidly developing salt spray corrosion test recently introduced internationally, conducted at a temperature of 50°C. A small amount of copper chloride is added to the salt solution, which dramatically accelerates corrosion. This test achieves a corrosion rate roughly eight times faster than the standard NSS test.

5. Salt Spray Test Standard

Among various standard systems, the following are recommended for evaluating salt-spray test results: *GB/T 1766—2008 Methods for Rating Aging of Paint and Coatings* and *GB/T 6461—2002 Rating of Test Samples and Specimens After Corrosion Testing on Metallic Substrates with Metallic and Other Inorganic Coatings*. To determine whether metal components on a product will corrode when exposed to atmospheric or other environmental conditions, one could place the product in its actual usage environment for an extended period—typically covering the product’s entire lifecycle. However, this approach is both time-consuming and labor-intensive, making it rarely practical in real-world applications. As a result, environmental simulation tests are far more commonly employed instead.